FAQ | SingularXYZ TS1000 Total Station – Part 1 Basic Settings
Total stations are vital tools in surveying and mapping, prized for their precision and adaptability. Mastering basic adjustments like system language, coordinate display, and units is essential for tailoring the instrument to your exact requirements. Drawing from our experience supporting TS1000 total station users, we've summarized some common settings in this blog to ensure your total station aligns perfectly with your needs.
Q1: Modifying the Instrument System Language
- Ensure the total station is powered off, then simultaneously press the F2 and power keys.
- Navigate to the language settings by pressing F4 (P↓).
- Select "LANGUAGE" using the F1 key.
- Use the F1 and F2 keys to choose the desired language, then press F4 (ENTER).
- Restart the total station to apply the language modification.
Q2: Modifying the NEZ/ENZ Display
- Make sure the total station is powered off, then press F2 and POWER simultaneously.
- Access the mode settings by selecting F2 (MODE SET).
- Scroll down twice by pressing F4 (P↓).
- Choose "NEZ/ENZ" by selecting F1.
- Use the F1 and F2 keys to select the desired display, then press F4 (ENTER).
- Restart the total station to implement the display modification.
Q3: Modifying the Instrument Constant
- Ensure the total station is powered off, then simultaneously press F1 and POWER.
- Access the instrument constant settings by selecting F2 (INST. CONSTANT).
- Use the F1 and F2 keys to navigate and modify the desired constants.
- After adjusting the parameters, press F4 (ENT).
These steps cover some fundamental setup for the TS1000 total station. If you have any questions about the usage of TS1000, please leave in the comment, we'll delve deeper into advanced settings and functionalities in the next chapter to further enhance your surveying experience with our product.
Learn more about SingularXYZ TS1000 total station